Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Deep Freezer |
| Coating | Color Coated |
| Tube Material | Copper |
| Shape | Rectangle |
| Country of Origin | Made in India |
A deep freezer coil is a critical component of the refrigeration system within a deep freezer. Its primary function is to absorb heat from the freezer's interior and maintain ultra-low temperatures, typically ranging from -18°C to -40°C or lower, depending on the application (commercial, industrial, or medical use).
Types of Coils in a Deep Freezer:Evaporator Coil (Cold Side):
Purpose: Absorbs heat from the internal space of the freezer.
Material: Usually made of aluminum or copper for better thermal conductivity.
Design: May be finned to increase surface area and heat exchange efficiency.
Location: Located inside the freezer cabinet, often embedded in the inner walls or placed behind a panel.
Condenser Coil (Hot Side):
Purpose: Releases absorbed heat to the surrounding air.
Material: Typically copper tubing with aluminum fins.
Location: Positioned outside the freezer cabinet, usually at the back or underneath the unit.
Refrigerant enters the evaporator coil in a low-pressure, cold liquid state.
It absorbs heat from the freezer's internal space and evaporates into gas.
The refrigerant gas travels to the compressor, which increases its pressure.
The high-pressure gas passes through the condenser coil, where it releases heat and condenses back into liquid.
The cycle repeats, keeping the freezer interior at a very low temperature.
Anti-corrosion coating for durability in low temperatures and moist environments.
Thicker insulation around coil lines to prevent energy loss.
Low-temperature compatibility refrigerants like R-404A or R-290.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Refrigeration |
| Tube Material | Stainless Steel |
| Shape | Rectangle/Square |
| Country of Origin | Made in India |
A chilled water coil is a finned-tube heat exchanger designed to cool air by circulating chilled water through its tubes. This specific coil is fabricated from SS304 stainless steel, known for its excellent corrosion resistance, mechanical strength, and durability, making it ideal for applicKey Features:
Tube Material: SS304 stainless steel (austenitic, non-magnetic, corrosion-resistant)
Fin Material: Aluminum or SS304 (optional, depending on corrosion requirement)
Headers/Manifolds: SS304
Casing/Frame: Galvanized steel, aluminum, or stainless steel (SS304 optional)
Fin Type: Corrugated or smooth, to enhance heat transfer
Tube Configuration: Typically 3/8", 1/2", or 5/8" OD, staggered or in-line pattern
Water Flow: Chilled water (typically 6–12 °C or 42–55 °F)
Applications: HVAC air handling units (AHUs), cleanrooms, hospitals, marine environments, and industrial cooling
Advantages of SS304 Coils:
Superior resistance to rust and corrosion, especially in coastal or chemically aggressive environments
Suitable for clean air and high-hygiene applications (e.g., food processing, pharmaceuticals)
Higher mechanical strength compared to copper
Long service life with minimal maintenance
Additional Information:
Product Details:
| Minimum Order Quantity | 1 sq ft |
| Tube Material | Copper |
| Fin Material | Aluminium |
| Material | Stainless Steel / Aluminum |
| Tube Diameter | 3/8", 1/2", 5/8" |
| Surface Treatment | Anti Corrosive Coating |
| Country of Origin | Made in India |
| Mounting Type | Wall Mounted |
| Construction | Galvanized Iron |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Coating | Color Coated |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 01 Piece |
| Rows | 2Rows to 18Rows |
| Usage/Application | AHU |
| Tube Diameter | 1/2 inch |
| Tonnage | 1TR to 500TR |
| Tube Material | Copper |
| Shape | Customized |
| Applications | Air Washer, FCU, Ductable AC, Packaged AC, AHU |
| Country of Origin | Made in India |
| product type | New |
Key features:
Construction: Copper tubes with aluminum fins (or SS304 for corrosion resistance in special applications) housed in a galvanized steel or stainless steel casing.
Working principle: Chilled water from a chiller plant flows through the coil tubes. Air blown across the fins transfers heat to the chilled water, providing cooling and often some dehumidification.
Applications: Air handling units (AHUs), fan coil units (FCUs), process cooling, and industrial air conditioning systems.
Performance factors: Coil surface area, fin spacing, water flow rate, and entering air/water temperatures determine cooling capacity.
Additional Information:
Air Cooled Heat Exchangers are widely used in industrial cooling systems to dissipate heat from process fluids into the atmosphere using ambient air as the cooling medium. They eliminate the need for water, making them highly suitable in areas with water scarcity. Built with finned tubes, axial fans, and sturdy frames, these exchangers ensure efficient heat transfer, low operating cost, and minimal maintenance. They are extensively used in oil & gas, petrochemical, power plants, fertilizer, chemical, and refinery industries. Designed for energy efficiency and long service life, air cooled heat exchangers are available in forced draft and induced draft types, ensuring customized cooling solutions for different applications.
🔑 Keywords in Paragraph FormatAir Cooled Heat Exchangers, ACHE, Industrial Air Cooled Heat Exchanger, Forced Draft Air Cooled Heat Exchanger, Induced Draft Air Cooled Heat Exchanger, Process Cooling Heat Exchanger, Petrochemical Air Cooled Heat Exchanger, Refinery Air Cooled Heat Exchanger, Power Plant Air Cooled Heat Exchanger, Energy Efficient Heat Exchanger